            MCT200 Coating Thickness Gauge

            Brand:

            Mitech

            Model:

            MCT200

            Measuring range:

            ?(0~1250) μm, depends on probes. maximum 10mm for the probe

            Resolution Accuracy:

            ±(3%H+1) μm;

            Communication storage:

            ?Memory for up to 20 files (up to 50 values for each file) o

            Working time:

            200 hours typical operating time (EL backlight off).

            Main unit weight:

            340g

            Dimensions:

            125*67*31mm

            Package dimensions:

            31.5*24.5*8.5cm

            Total weight:

            1.4kg

            Product

            • Overview
            • Graphic
            • Technical
            • Configuration
            • Related

            Product

            • Overview
            • Graphic
            • Technical
            • Configuration
            • Related
            • Product Overview

              MCT200 Coating Thickness Gauge is designed for non-destructive, fast and precise coating thickness measurement and also can measure the film thickness. It is widely used in manufacturing,metal processing industry, chemical industry.commodities inspection and other testing areas. Measuring range from 0 to 10 mm, can meet the different industries in view of the workpiece surface coating thickness testing requirements. It is the necessary professional precision instrument to improve the production efficiency and the qualified rate, saving the cost of production.

              Function & application

              Five types of probes are available for different application,probe contact parts with the hard chrome or red ruby materials, very durable.

              With different external probes,the gauge can be applied to measuring thickness of

              non-magnetic coating on magnetic metal substrate,as well as non-conductive coating on non-magnetic metal substrate. 

              Two calibration methods can be applied to the gauge and the system error of the probe can be corrected with the basic probe calibration method. 

              Two measuring modes: single or continuous, changeable.

              Measuring status indicator shows the measuring status. 

              EL display back light ensures easy reading of screen data in low light conditions. 

              Battery information indicates the rest capacity of the battery.

              Auto sleep and auto power off function to conserve battery life.

              USB1.1 communication port.

              Optional software to process the memory data on the PC.

              Compact aluminum case, suitable for use under poor working conditions.

              Working Principle

              Measuring principle: Magnetic induction & Eddy current.

              With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic Metal substrate,as well as non-conductive coating on non-magnetic metal substrate.

              Working Conditions

              Working temperature: -10℃~+50℃.

              Storage temperature: -30℃~+60℃.

              Relative humidity: ≤90.

              The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

              Instrument Features

              Five types of probes(F400,F1, F10,N1,CN02) are available for different applications, F10 probe measures up to 10mm.

              With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate.

              Two calibration methods can be applied to the gauge.The system error of the probe can be corrected with the basic probe calibration method.

              Two measuring modes: single or continuous, changeable.

              Measuring status indicator shows the measuring status. 

              Measured values and user information are shown on a large, easy-to-read LCD.The display back light ensures easy reading of screen data in low light conditions.

              Battery information indicates the rest capacity of the battery. 

              Auto sleep and auto power off function to conserve battery life. 

              USB1.1 communication port, optional software to process the memory data on the PC.

              The gauge equips with data-pro software, can do measurement results transmission, automatic storage management, measurement data analysis, measurement reports print etc.

              Compact aluminum case, suitable for use under poor working conditions.

              Operating Method and Attentions

              When the instrument is off, press CAL then press start, with a beep, enter the calibration mode, set the probe zero point.

              Test on the specimen, use up/down to retify the valus, then follow the step on the other four slices. In asending order, such as, 50, 100, 200, 400, 800μm. The instrument should avoid humidity, unplug the plug with care, keep clean.

              Instrument Maintenance

              The battery should be changed when almost out, used batteries must be removed from the gauge without delay to avoid leakage, please take out the batteries when not using.

              The calibration substrate should avoid scratch, rust.

            •  

            • Measuring range (0~1250) μm, depends on probes. maximum 10mm for the probe F10.
              Resolution 0.1μm
              Accuracy ±(3%H+1) μm;
              Display 4 digital LCD with EL backlight
              Storage Memory for up to 20 files (up to 50 values for each file) of stored values.
              Unit Metric (μm)、Imperial (mil)
              Working voltage Two “AA” size, 1.5 Volt alkaline batteries.
              Working hous 200 hours typical operating time (EL backlight off).
              Communication port USB1.1
              Dimensions 125mm×67mm×31 mm
              Net weight 340g
              Working temperature -10℃~+50℃
              Relative humidity ≤90%
            • Ferrous Probe F1
              F1 probe is made based on the magnetic induction principle and should be used for non-magnetic coatings such as aluminum, chrome, copper, zinc, paint and varnish, enamel, rubber etc., on an iron or steel substrate.
              F1 probe or N1 probe can be the standard config.
              Measuring range (um):0-1250μm;
              Min curvature of the min area(mm):1.5mm;
              Critical thickness of substrate (mm):0.5mm;
              Diameter of the min area (mm): Φ7;
              Probe cable length: 90cm;
              It is plated with hard chrome, durable, not easy to wear;
              The error caused by the probe is small, the measured value is accurate;
              F1 probe is made of metal which can effectively protect the probe, corrosion-resistant and vibration-proof,  durable;
              It is widely used to measure the thickness of non-magnetic coatings such as copper plating, rubber layer and paint layer on the magnetic metal materials such as iron and steel.
              In the manufacturing and metal processing industry, chemical industry, commodity inspection and other detection areas and material protection in the
              Standard Foils
              The foils of Mitech coating thickness gauge, also called as coating thickness gauge foils, used for instrument calibration in laboratory, production line or on-site, they are the necessary accessories for coating thickness gauge. It is the most convenient method for instrument calibration by establishing the thickness standard on the substrate. There are five pieces of standard foils in the standard configuration of the coating thickness gauge. Their thickness is about 50μm、100μm、250μm、500μm、1000μm respectively, which can meet the requirements of various calibration like single point calibration, two point  calibration and multi-point calibration.
              Ferrous standard substrate F1
              The ferrous standard substrate F1 of coating thickness gauge, used for the zero calibration for F1 probe or matching with standard foils. The working principle is still using the magnetic method. With working principle of the magnetic method, when the probe and zero-calibration substrate contact, the probe head and magnetic metal substrate form a closed magnetic circuit, due to the non magnetic layer exists, the magnetic reluctance changes. With measuring the change, the layer thickness can be deduced to achieve the purpose of measuring the coating thickness on the ferrous substrate.
              ABS instrument case
              Carry case for coating thickness gauge, length: 25cm, height:6cm,width: 21cm,weight: 0.628kg. It is made of  ABS engineering plastic sealed waterproof, anti-throw shock, heat resistance, low temperature resistance and other excellent properties, which can effectively defense in the severe environment pollution, dust and all kinds of corrosion, measures for air, train carrying standard (can be put under the seat in and the rack), small and convenient can be placed in the backpack, safe, reliable and stable.
              AA size alkaline battery
              Two “AA” size alkaline batteries are the standard config.it support 200 hours continuous operating time (EL backlight off).
              Attached files
              Mitech coating thickness gauge with customized packing documents including product certificate, warranty card, product manual, packing list. The packing documents had used the special printed paper. The manual is with graphic design, beautiful, easy to understand, easy to save for a long time.
              Note: The electronic version of the packing documents for Mitech series products can be downloaded from www.dcycfz.com.
            • Non-ferrous probe N1
              N1 probe works on the eddy-current principle and should be used for insulating coatings on all non-ferrous metals;
              F1 probe or N1 probe can be the standard config.
              Measuring range (um):0-1250μm;
              Min curvature of the min area(mm):3mm;
              Critical thickness of substrate (mm):0.3mm;
              Diameter of the min area (mm): Φ5;
              Probe cable length: 90cm;
              It is plated with hard chrome, durable, not easy to wear;
              The error caused by the probe is small, the measured value is accurate;
              N1 probe is made of metal which can effectively protect the probe, corrosion-resistant and vibration-proof,  durable;
              It is widely used in measuring the rubber layer and paint layer and other non-conductive coating thickness on aluminum, copper and other conductive materials;
              In the manufacturing and metal processing industry, chemical industry, commodity inspection and other detection areas and material protection in the professional scientific research, it is necessary precision instrument.

              Ferrous Probe F10
              F10 probe is made based on the magnetic induction principle and should be used for non-magnetic coatings such as aluminum, chrome, copper, zinc, paint and varnish, enamel, rubber etc., on an iron or steel substrate.
              F10 probe is optional config.
              Measuring range (um):0-10000μm;
              Min curvature of the min area(mm):10mm;
              Diameter of the min area (mm): Φ40;
              Critical thickness of substrate (mm):2mm;
              Probe cable length: 90cm;
              It is plated with hard chrome, durable, not easy to wear;
              The error caused by the probe is small, the measured value is accurate;
              F10 probe is made of metal which can effectively protect the probe, corrosion-resistant and vibration-proof,  durable;
              It is widely used to measure the thickness of non-magnetic coatings such as copper plating, rubber layer and paint layer on the magnetic metal materials such as iron and steel.
              In the manufacturing and metal processing industry, chemical industry, commodity inspection and other detection areas and material protection in the professional scientific research, it is necessary precision instrument.


              Ferrous Probe F400
              F400 probe works on the magnetic induction principle and should be used for non-magnetic coatings such as aluminum, chrome, copper, zinc, paint and varnish, enamel, rubber etc., on an iron or steel substrate.
              F400 probe is optional config.
              Measuring range (um):0-400μm;
              Min curvature of the min area(mm):1mm;
              Diameter of the min area (mm): Φ3;
              Critical thickness of substrate (mm):0.2mm;
              Probe cable length: 90cm;
              It is plated with hard chrome, durable, not easy to wear;
              The error caused by the probe is small, the measured value is accurate;
              F400 probe is made of metal which can effectively protect the probe, corrosion-resistant and vibration-proof,  durable;
              It is widely used to measure the thickness of non-magnetic coatings such as copper plating, rubber layer and paint layer on the magnetic metal materials such as iron and steel.
              In the manufacturing and metal processing industry, chemical industry, commodity inspection and other detection areas and material protection in the professional scientific research, it is necessary precision instrument.

              Ferrous Probe F1/90°
              F1/90°probe works on the magnetic induction principle and should be used for non-magnetic coatings such as aluminum, chrome, copper, zinc, paint and varnish, enamel, rubber etc., on an iron or steel substrate.
              F1/90°probe is optional config.
              Measuring range (um):0-1250μm;
              Min curvature of the min area(mm):1.5mm;
              Diameter of the min area (mm): Φ7;
              Critical thickness of substrate (mm):0.5mm;
              Probe cable length: 90cm;
              It is plated with hard chrome, durable, not easy to wear;
              The error caused by the probe is small, the measured value is accurate;
              F1 probe is made of metal which can effectively protect the probe, corrosion-resistant and vibration-proof,  durable;
              It is widely used to measure the thickness of non-magnetic coatings such as copper plating, rubber layer and paint layer on the magnetic metal materials such as iron and steel.
              In the manufacturing and metal processing industry, chemical industry, commodity inspection and other detection areas and material protection in the professional scientific research, it is necessary precision instrument.
              USB cable and datapro software
              USB cable & Datapro Software, can coonect to PC , opptioanl accessories. Datapro Software has rich functions sucg as data storage management, data statistical analysis,printing reports,batch setting parameters and so on. Suitable for mechanical processing and manufacturing, automobile manufacturing, textile standard parts, hardware accessories and instrument accessories and other related to the metal material products manufacturing enterprises. Using the software provides the analysis of the results, can make the enterprise more scientific basis for quality control, traceability is higher, improve the quality of the enterprise information management level.It is the effectuve gurarantee to  improve the quality monitoring and  enteprises to  analysis product qualified rate .It also is the basic scientific research  effective tool to be as metal materials related scientific research units, factories, universities and colleges, such as departments engaged in theoretical teaching, experimental analysis
            ×

            郵箱反饋

            如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
            您也可以撥打我們客戶服務(wù)熱線:400-0600-280

            *
            *

            MITECH CO. LTD

            TEL :

            86-10-58859527
            008613810243516

            ADD:

            E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

            Email: 

            mvip@mitech-ndt.com

            公眾號
            亚洲AV无码国产精品久久久麻豆,国产精品无码1区2区,人妻无码啪啪AV交,亚洲AV综合色区无码国产播放 (function(){ var bp = document.createElement('script'); var curProtocol = window.location.protocol.split(':')[0]; if (curProtocol === 'https') { bp.src = 'https://zz.bdstatic.com/linksubmit/push.js'; } else { bp.src = 'http://push.zhanzhang.baidu.com/push.js'; } var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(bp, s); })();