            Mitech MHRS-150T Cantilever Rockwell Hardness Test

            Brand:

            Mitech

            Model:

            Measuring range:

            HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、 HRF:60

            Resolution Accuracy:

            Communication storage:

            Working time:

            Main unit weight:

            Dimensions:

            700*250*600mm

            Package dimensions:

            85*48*76cm

            Total weight:

            120kg

            Product

            • Overview
            • Graphic
            • Technical
            • Configuration
            • Related

            Product

            • Overview
            • Graphic
            • Technical
            • Configuration
            • Related
            • Product Overview

               Mitech MHRS-150T Cantilever Rockwell Hardness Tester, also known as convex nose dual Rockwell hardness, based on the mechanical principle of conical diamond or hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation. With novel appearance, stable performance, touch screen operation easy and real-time monitoring test environment temperature, it can solve the problem of ring, tube, groove type workpiece surface, convex workpiece surface while other general Rockwell hardness tester can not measure the workpiece Rockwell hardness testing requirements. it is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions, and it is the precise and high-tech equipment to test the metal materials Rockwell hardness.

              Function & application

              l Used for quality control in metal processing manufacturing

              l Used for failure analysis testing of metallic materials;

              l Demonstration experiment for education and teaching in Colleges and Universities;

              l Hardness testing of materials in scientific research institutions

              Working Principle

              The Rockwell hardness test is taking the diamond cone with 120°apex angle or the hardened steel ball with specified diameter as the indenter to press into sample surface with specific test force, then get the Rockwell hardness of the measured metallic materials according to the sample surface indentation depth.

              The Rockwell hardness measurement principle is shown as below figure. 0-0 is the position that the diamond indenter is not yet in contact with the sample. 1-1 figure is the indenter position under the affect of the preliminary test force, the indentation depth is h1. The preliminary test is to eliminate the influence to the testing result accuracy caused by the roughness of the sample surface. 2-2 in the figure is the indenter position under the influence of the testing force (the preliminary test force and the main test force). The depth is h2. 3-3 in the figure is the indenter position after dismounting the main test force. As the metal elasticity will recovery some degree after deformation, the really indentation depth of the indenter is h3. The plastic deformation caused by the main test force make the indenter pressing into the depth is hh3h1. Rockwell hardness value is determined by the size of h, the greater the depth h, the lower the hardness, otherwise, the higher the hardness.

              In the traditional concept, usually use a constant C minus h to represent the level of hardness, while the depth of indentation per 0.002mm as a unit of hardness. The hardness value obtained is called the Rockwell hardness value, denoted by the symbol HR.

               In the formula, c is a constant (for HRC, HRA, c is 0.2; for HRB, c is 0.26). The Rockwell hardness value HR obtained is an unknown number which is usually read directly on the test machine indicator when testing.

                 It should be noted that the measured hardness values would be different with different indenter and test force. Therefore, the Rockwell hardness testing specifies 15 different hardness test scales according to the different indenter specification and test force sizes. And the HRB, HRC, HRA are the most widely used.  

              Working Conditions

              Operation Temperature1030℃;

              Relative Humidity≤65%;

              The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

              Instrument Features

              l Widely used in the ring, tube, groove type workpiece surface, it can test the convex parts of the workpiece and the

               workpiece Rockwell hardness and surface Rockwell hardness that other general Rockwell hardness tester can not

               measure;

              l Adopt large-screen LCD, easy to operate, visually display the test results;

              l Equipped with excellent performance of cemented carbide or diamond indenter, high hardness, wear resistance, good

               toughness, with high temperature, corrosion resistance, to ensure that the instrument test value is accurate, stable and

               reliable;

              l With the function of error value correction, the hardness value of the error can be automatically modified by key input,

               easier to meet the test accuracy requirements;

              l Support the conversion among various hardness scales such as Brinell, Vickers and etc;

              l With the function of threshold overrun automatic alarm, which applies to the bulk of finished products or semi-finished

               pieces of paper-by-piece detection;

              l Option for various specifications of the indenter, support 15 types of Rockwell hardness scales testing;

              l The function of original ambient temperature real-time display can avoid the instrument working in the case of high or low

               temperature for a long time , resulting in increased test error and reducing the service life;

              l Equipped with high-speed thermal printer, real-time print test results;

              l Consistent with EN-ISO-6508、GB/T230.1、GB/T230.2、JJG112、ASTM E18 and other relevant standards at home and

               abroad.

              Operating Method and Attentions

              Instrument Maintenance

              l The test personnel should follow the operating procedures.Before and after the test,it  should be repeated with standard

               block calibration equipment;

              l The hardness value needs to be corrected when the measured surface specimen is less than 38 (25) mm.

              l If the specimen has visible deformation marks on the back and edges, the test result would be useless. It should choose

               the intender or test force to test again;

              l Normally, the first point is only used to offset the gap of each support surface without needing to record the test result.

               Record the statistical test result from the second point;

              l During testing, to ensure accuracy, please make sure the distance between the adjacent indentation center and the

               distance from the indentation center to edge of the specimen is greater than 3mm;

              l Pay attention to palm the instrument for carrying to forbid falling across. Please fix well the measuring lever, counterweight

               and boom before carrying;

              l It is strictly prohibited to turn the variable loading handwheel when the instrument load or unload the test force. Rotating

               the handwheel forcibly will cause the internal gear dislocation, test force in chaos and even damage the internal parts of

               the instrument;

              l Turn off the power after using the instrument;

              l When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the

               hardness block, indenter should be coated with antirust oil to prevent rusting after using;

              l Long time after the re-enabled,it should be preheated the electrical components before test

              l The hardness tester should be calibrated at least once a year to ensure its accuracy;

              l Don’t disassemble the instrument without authorization, for maintenance related matters, please contact MITECH 

              after-sale service department with 4000600280.

            • Preliminary testing force 29.4N、98.07N,tolerance±2.0%
              Testing force 147.1N,294.2N,441.3N,588.4N,980.7N,1471N,tolerance±1.0%
              Measuring range HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、 HRE:70-100、 HRF:60-100、HRG:30-94、HRH:80-100、HRK:40-100、HRL
              Testing force application Mode Automatic operation (preliminary test force needs manual operation)
              Indenter specification Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter
              Display LCD
              Rockwell scale HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、HRL、HRM、HRP、HRR、HRS、HRV
              Conversion scale HV、HBW、HK
              Indication error 0.01HR
              Duration time 1~30s
              Maximum height of specimen 200mm
              Distance of indenter to outer wall 150mm
              Power supply AC220V/50Hz
              Dimension 700*250*600mm
              Main unit weight 100kg
            ×

            郵箱反饋

            如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
            您也可以撥打我們客戶服務(wù)熱線:400-0600-280

            *
            *

            MITECH CO. LTD

            TEL :

            86-10-58859527
            008613810243516

            ADD:

            E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

            Email: 

            mvip@mitech-ndt.com

            公眾號
            亚洲AV无码国产精品久久久麻豆,国产精品无码1区2区,人妻无码啪啪AV交,亚洲AV综合色区无码国产播放 (function(){ var bp = document.createElement('script'); var curProtocol = window.location.protocol.split(':')[0]; if (curProtocol === 'https') { bp.src = 'https://zz.bdstatic.com/linksubmit/push.js'; } else { bp.src = 'http://push.zhanzhang.baidu.com/push.js'; } var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(bp, s); })();